Outage verification system map: the keys that join calls, events, work orders and meter checks

Short answer

Reconstructing a verified outage restoration takes five links: the call ID that ties each trouble call to an outage event, the event ID that ties the event to a work order, the asset ID that ties the work order to the device actually repaired, the parent-child event link that ties a nested outage to the closure it contradicted, and premise or meter IDs with timestamps that tie each restoration check to the customers it covered. Each link lives in a different system and usually has a different owner. Lose the parent-child link and a hidden second failure looks like an unrelated outage.

Visual briefFull-size diagram
A system map with the outage platform at the center and four systems around it: the call platform linked by call ID, the asset system by work order number and asset ID, the meter data system by meter ID and time, and the callback log by event ID. Key labels travel along each link to join one restoration case.
Illustrative map; which keys a given utility stores depends on its products and how they were configured.

This map supports the outage work order verification guide. It is for consultants who need to tell a client's operations director which joins matter before anyone discusses records.

Five systems behind one restoration

A utility's restoration history rarely sits in one product. A typical mid-sized distribution utility spreads it across:

  • Call platform or IVR, where customers report the outage and the call gets an ID.
  • Outage platform, which groups calls into events, predicts the failed device, assigns crews and records restoration steps.
  • Asset or work management system, where the work order and the repaired asset live.
  • Meter data system, which may record power-off and power-on events by meter.
  • Callback log, a module, spreadsheet or call center list showing who was rung back and what they said.

Some outage platforms can model restoration as related events rather than single tickets. Oracle's Network Management System user guide has sections on related partial restoration events, updating multiple events and completing an event. How a given utility configured those features, and what its asset system stores against each work order, varies by product, version and implementation, so every row below is a question for the administrator, not an assumption.

The map: which system holds what, and the key that joins it

SystemRecord it holdsLinking key to the next systemUsual owner
Call platformTrouble call with time and premiseCall ID carried onto the outage eventMember or customer services manager
Outage platformEvent, predicted and confirmed device, crew assignment, restored time per stepEvent ID written onto the work orderOperations director
Outage platformNested or partial restoration eventParent event ID on the child eventOperations director
Asset or work management systemWork order, asset worked, completion timeWork order number and asset IDAsset management lead
Meter data systemPower-off and power-on eventsMeter or premise ID plus timestampMetering manager
Callback logCustomer confirmations after restorationEvent ID and premiseControl room supervisor

Two keys carry most of the weight. The event ID on the work order joins field action to the outage, and the parent event ID joins a correction to the closure it overturned. If either is missing, the history still exists, but it no longer tells one story.

One fully joined case (Illustrative)

A fictional case, invented for this page, for a 470-person electric and water utility. Identifiers are placeholders, not real formats.

StepSystemWhat the record saysKey used to join
ReportCall platform14 calls from one rural road after a wind gustCall IDs attached to event 1
EventOutage platformRecloser predicted locked out; 120 customersEvent 1
Work orderAsset systemReset recloser; asset recorded as the recloserEvent 1 on work order A
ClosureOutage platform and asset systemRecloser reset; event 1 marked restoredWork order A completion time
CheckMeter data system112 meters report power-on; 8 report noneMeter IDs on event 1 premises
Nested eventOutage platformChild event for 8 customers, broken service dropParent event 1 on event 2
Second orderAsset systemRepair service dropEvent 2 on work order B
VerifiedCallback logAll 8 confirmed backEvent 2 and premises

Read across the last column. Every hop used a different key, and the case only reads as one restoration because each key was stored. The worked exception case walks a similar sequence step by step from the decision-makers' side.

Where the joins fail after migrations and handovers

LinkWhat breaks itWhat the history looks like afterwards
Call ID to eventCalls archived separately from eventsEvents with customer counts but no reports
Event ID on work orderWork orders created by hand during stormsField work that cannot be tied to an outage
Asset IDPredicted device never corrected to confirmed deviceThe wrong asset appears to have failed
Parent event IDChild events migrated as stand-alone outagesTwo unrelated outages instead of one correction
Meter ID and timeMeter events purged on a short retention ruleRestoration checks acted on but unprovable

The industry treats these hand-offs as interfaces in their own right. IEC 61968-1 sets out an interface reference model for exchanging information between distribution management functions, naming outage management, work management, network model management and metering among them. A utility that integrated its systems along those lines is more likely to have kept keys at each hop; one that relied on manual re-keying during storms is more likely to have gaps. Either way, the administrator's answers, not the standard, say what exists.

Questions for the outage platform administrator

Ask in one conversation and record only the answers:

  1. Does each work order carry the outage event ID, and since what year?
  2. Are nested or partial restoration events linked to their parent, and does the link survive export?
  3. Is the confirmed device stored separately from the predicted one?
  4. How long are meter power-on events retained, and can they be matched to events?
  5. Are callbacks logged in a system, or only worked from a list?

Partners never ask for exports, data dictionaries or logins. Note quality is a separate question, covered in assessing field service records and resolution notes; the wider category is on field service histories, and why cross-system data carries more value explains why the joins matter to AI labs and data users at all. The asset-side migration risk is covered in CMMS migration.

Who owns the joins, and qualification

Each system has its own administrator, and none of them decides on licensing. The operations director convenes; the CEO or general manager decides, with counsel. When the map is filled in, carry the answers into the outage verification referral brief.

The utility needs 50+ full-time employees at peak (contractors excluded), documented operating history, rights to license and an authorized contact. Companies in the U.S., Canada and the EU qualify, as do companies in the UK, Australia, New Zealand, India, Singapore, South Africa, Latin America, the UAE and Saudi Arabia when at least 90% of the data is in English. What stays unknown until SourceX reviews it: demand for joined restoration histories, the rights result for customer-linked and network fields, the preparation required and any offer. Partners sign the Channel Partner Agreement before submitting, and the first valid introduction within the 90-day window is credited when the company submits a verified application.

Next step

Refer a company. Earn up to $100,000. Default reward: 25% of Actual Supplier Payout, capped at $100,000 cumulatively per referred company. Eligibility and payment conditions apply, and a signed Schedule A or addendum can differ. A lead, meeting or signature alone does not trigger payment.

If the administrator confirms that event IDs reach the work orders and nested events keep their parent, register as a partner, check the utility on who qualifies and read the program terms before you introduce the operations director.

  1. Step 1Share your linkSend your personal link to a company you know.
  2. Step 2Company appliesThe company applies itself at /apply.
  3. Step 3Company signs and is paidThe company signs, delivers its data and is paid by SourceX under its agreement.
  4. Step 4You get your rewardYour 25% of the actual supplier payout. A reward becomes payable after SourceX has paid the referred company under its signed agreement and the payout conditions in the program terms are met, including finance approval and your tax and payment details.

Common questions

Is the event ID enough to join everything?

Usually not. It joins calls and crew assignments on the outage platform, but the asset system may know only the work order number and the asset worked, and meter data knows only premises and timestamps. Each hop needs its own key.

What if work orders were created by hand without an event reference?

Then the join falls back to asset and time window, which works for some cases and fails for busy storm nights. Record the share of work orders that carry an event reference, if the administrator can estimate it.

Should a partner ask for the outage platform's data dictionary?

No. Ask the administrator which of the keys on this page are stored and since when, and write down the answers. Documentation, exports and screenshots stay with the company.

Sources

  1. docs.oracle.com/en/industries/energy-water/network-managemen…
  2. webstore.iec.ch/en/publication/32542
  3. refer.sourcex.si/terms

Free resources

Know a company with valuable proprietary data?

Become a referral partner, get your link and introduce the company’s CEO (in an owner-run company, usually the owner). Referral partners can join from most countries. We can't work with partners in countries or regions under U.S. sanctions or on U.S. restricted-party lists. The companies you introduce should be based in the U.S., Canada and the EU, or in the UK, Australia, New Zealand, India, Singapore, South Africa, Latin America, the UAE and Saudi Arabia with at least 90% of their data in English.

Refer a company →

I own a business

Explore licensing your company's data directly to SourceX for AI training and evaluation. Start a short assessment; no uploads needed.

Start an assessment